ENH 324 Lecture Notes - Lecture 6: Septic Tank

125 views2 pages

Document Summary

Class 5 sewage system (inspectors are not allowed to design any class of sewage systems) Article 8. 8. 1. 2. a: acceptable installation if proposed is for temporary operation, excluding seasonal/recreational use, not exceeding 12 months) Also where class 4 is is impracticable (so used to remedy that: b/c class 4 is not possible due to lot size, site slope, clearance limitations so upgrading sewage system of existing building. Terminates at least 3. 5 m away from any air inlet, window, or dor. A vent from a ht may connect to the venting system of the building provided that: the bent is not less than 3 inch trade size & installation of vent conforms to requirements: clearances for ht. Ht must be located on the lot w/ minimum clearance distances from: 1. 5 m from structure: 15 m from a well w/ a water tight casing to a depth of at least 6m, 15 m from any other well.