Lab 4: Determination of an Equilibrium Constant
Objectives:
To determine the concentration of iron (III) thiocyanate ions, FeSCN2+, in various iron (III)
nitrate, Fe(NO3)3, and potassium thiocyanate, KSCN solutions. The results of these measurements
will determine the equilibrium constant for the formation of FeSCN2+.
Introduction:
Chemical reactions occur to reach a state of chemical equilibrium. The equilibrium state can be
characterized by specifying its equilibrium constant. In this experiment you will determine the
value of the equilibrium constant for the reaction between the iron (III) ion, Fe3+, and thiocynate
ion, SCN-.
Fe3+(aq) + SCN-(aq) FeSCN2+(aq) (1)
where
2+¿
FeSCN¿
¿
3+¿
Fe¿
¿
¿
SCN ¿
¿
¿
¿
Keq=¿
(2)
To find the value of Keq, it is necessary to determine the concentration of each of the three species
in solution at equilibrium. This can be done using UV-visible spectroscopy.
Part A - Determination the Calibration Curve of FeSCN2+ by Spectrometry
When a chemical reaction reaches chemical equilibrium, the rates of the forward and the reverse
reactions are equal. The concentrations of all the species become constant. In this experiment, we
take advantage of the fact that FeSCN2+ is a coloured compound and that the concentration of this
compound can be determined by measuring its absorbance using spectrophotometric methods.
This method requires a calibration curve using samples of known concentration.
Beer's law relates absorbance, A, the light absorbed on passing through a length of solution, , of
a concentration, c, of the absorbing solute. According to Beer's law, the amount of light absorbed
by a coloured species in solution at a specific wavelength is directly proportional to the
concentration of the coloured species.
A = ε · · c (3)
3cc08efe141a44d615ee4eff9905f4 4-1

Only pages 1-2 are available for preview. Some parts have been intentionally blurred.

The absorbance is measured for a series of standard solutions with known concentrations. If a
solute obeys Beer's law, according to equation (3), a graph of the "Absorbance versus
Concentration" will yield a straight line of slope equal ε . This is known as a calibration curve
for the solute. From the calibration curve, the absorbance of the solute with an unknown
concentration can be determined. In usual practice of this technique, a blank is used to cancel out
absorption by any other solutes, so that the measured absorbance is directly proportional to the
concentration of the solute of interest. This is routinely done by people working in the fields of
medicine, forensic science, and chemistry.
In this lab, the solute of interest is FeSCN2+. A series of standard FeSCN2+ solutions will be
prepared from solutions of varying concentrations of SCN- and constant, high concentrations of
Fe3+ and H+. The high concentration of the Fe3+ ion, relative to that of the SCN- ion, drives
equilibrium (1) to the right; essentially to completion. Solutions of Fe3+ are weakly coloured and
the SCN- ion is colourless. The primary absorber in the mixture will be the FeSCN2+. FeSCN2+ is
known to obey Beer's law over a wide range of concentrations with maximum absorption at a
wavelength of 447 nm. Thus, this wavelength will be used to make measurements of the FeSCN2+
concentration in equilibrium mixtures. The high [H+] will ensure that the iron (III) ion will not
form the insoluble compound, iron (III) hydroxide. The high [Fe3+] will ensure that all SCN-
reacts to form FeSCN2+. The FeSCN2+ complex forms slowly in about 1 minute and then it
decomposes slowly due to its reaction with light. For best results, the absorbance value should be
read between 2 and 4 minutes after preparation and all samples read after the same time interval.
Part B - Determination of an Equilibrium Constant
A second series of solutions will be prepared for the determination of the equilibrium constant.
These solutions will have a fixed high concentration of H+, a constant low concentration of Fe3+
and varying low concentration of SCN-. The absorbance readings will enable the equilibrium
concentration of FeSCN2+ to be determined directly.
The Fe3+ ion is obtained from a solution of Fe(NO3)3 which total dissociates to give
Fe(NO3)3(aq) Fe3+(aq) + 3 NO3-(aq).
Therefore the initial [Fe3+]o = [Fe(NO3)3]o. Similar, the SCN- ion is obtained from a solution of
KSCN which total dissociates to give
KSCN(aq) K+(aq) + SCN-(aq).
Therefore the initial [SCN-]o = [KSCN]o. The equilibrium concentrations of Fe3+ and SCN- can be
calculated from their initial concentrations and the equilibrium concentration of FeSCN2+.
Procedure:
Part A - Determination the Calibration Curve of FeSCN2+ by Spectrometry
Note: For Part A of the experiment, we will be using the 0.150 M Fe(NO3) 3 and 5.00x10-4 M
KSCN solutions. Assume that all of the SCN- is present as the complex ion, FeSCN2+ due to the
high concentration of Fe3+.
Work in pairs.
Deliver all volumes of Fe3+ solutions with a 10.0 mL bottle top dispenser and SCN-
solutions using a burette.
Add the solutions into a 25.00 mL volumetric flask and dilute to the mark with 0.10 M
nitric acid.
3cc08efe141a44d615ee4eff9905f4 4-2
You're Reading a Preview

Unlock to view full version

Only pages 1-2 are available for preview. Some parts have been intentionally blurred.

All cuvettes should be wiped clean and dry on the outside with a tissue.
All solutions should be free of bubbles.
Always position the cuvette with its reference mark facing the reference mark on the
spectrophotometer.
1. Turn on the spectrophotometer, set Mode to Absorbance, and set the wavelength to 447 nm.
2. Prepare solutions according to Table 1 using 25.00 mL volumetric flasks. Dilute to the mark
with 0.10 M HNO3 and mix well.
Solutions #
1
(Blank
)
2 3 4 5 6
mL of 0.150 M Fe(NO3)3 in 0.10 M HNO3
use a bottle-top dispenser 10.00 10.0
0
10.0
0
10.0
0
10.0
0
10.0
0
mL of 5.00x10-4 M KSCN in 0.10 M HNO3
use a burette 0 2.00 3.00 5.00 7.00 9.00
Table 1: Volume of reagents used to make solutions.
3. Obtain a clean cuvette and rinse (2x with small portions) with Solution #1, the blank solution,
and fill the cuvette ¾ full. Wipe the outside of the cuvette and avoid touching the bottom half
of the cuvette. Insert the cuvette into the sample compartment with its orientation mark
aligned with the mark in the spectrophotometer and set the absorbance to read 0. This is the
absorbance of unreacted Fe3+ in the solution. All the standards have a large excess of Fe3+,
which absorbs light in this wavelength region.
4. Empty the cuvette and rinse (2x with. small portions) with Solution #2 and fill the cuvette ¾
full. Wipe the outside of the cuvette and avoid touching the bottom half of the cuvette.
5. Insert the cuvette filled Solution #2 and read the absorbance of the solution.
6. Repeat Step 4 and 5 to prepare and measure the absorbance for Solutions #3 to #6 in order of
increasing SCN- concentration and read the absorbance of each sample once the solution is
prepared. Remember to rinse the cuvette with each sample.
7. Check that the absorbance values are in direct proportion with one another so the graph will
be linear. Prepare alternate solutions to any which fall outside the linear region and measure
the absorbance.
8. Calculate [FeSCN2+] for each solution and enter the concentrations on the datasheet. Show a
sample calculation for Solution #3
9. Plot a calibration graph of net absorbance versus [FeSCN2+]. Include the (0, 0) point. Clearly
label the graph. Obtain the equation of the straight line for the calibration graph written in
terms of the variables used in this experiment. Attach the graph to the report sheet.