Objective : Calculate the molar mass of CO2 (dry ice). Make sure this is handwritten in the lab notebook.
Procedure :
Note : During the lab, look for a qualitative observation that proves CO2(g) is denser than air.
(1)Weigh the empty 250mL Erlenmeyer flask with a rubber stopper on.
(2)Obtain few small pieces of CO2(s) in the flask. The total amount should be close to the given rubber stopper in size. Let it sublime. Make sure the pieces are small enough so you can see them âsingâ and âdanceâ.
(3) When sublimation is done, cap it with the stopper and weigh it. We are assuming that the container is completely filled with CO2 at this point.
(4) Measure the temperature of CO2.
(5) Fill the flask all the way to the rim with water and put the rubber stopper on. Water will spill over. Pour the water into 50mL/100mL graduated cylinder (multiple times) and measure the total volume of water.
(6) Measure pressure of the air using the barometer on the wall.
Analysis
(A1) Calculate the moles of CO2 using PV=nRT.
(A2) Calculate the molar mass of CO2.
Question:
I have provided all of the procedure.
ANswer this question only -->
What would happen to the final result if the CO2(s) sample was too small (not enough) to fill the flask?
<--
answer this one question above clearly. explain step by step.
thanks
Objective : Calculate the molar mass of CO2 (dry ice). Make sure this is handwritten in the lab notebook.
Procedure :
Note : During the lab, look for a qualitative observation that proves CO2(g) is denser than air.
(1)Weigh the empty 250mL Erlenmeyer flask with a rubber stopper on.
(2)Obtain few small pieces of CO2(s) in the flask. The total amount should be close to the given rubber stopper in size. Let it sublime. Make sure the pieces are small enough so you can see them âsingâ and âdanceâ.
(3) When sublimation is done, cap it with the stopper and weigh it. We are assuming that the container is completely filled with CO2 at this point.
(4) Measure the temperature of CO2.
(5) Fill the flask all the way to the rim with water and put the rubber stopper on. Water will spill over. Pour the water into 50mL/100mL graduated cylinder (multiple times) and measure the total volume of water.
(6) Measure pressure of the air using the barometer on the wall.
Analysis
(A1) Calculate the moles of CO2 using PV=nRT.
(A2) Calculate the molar mass of CO2.
Question:
I have provided all of the procedure.
ANswer this question only -->
What would happen to the final result if the CO2(s) sample was too small (not enough) to fill the flask?
<--
answer this one question above clearly. explain step by step.
thanks
For unlimited access to Homework Help, a Homework+ subscription is required.
Related textbook solutions
Basic Chemistry
Principles of Chemistry Molecular Approach
Principles of Chemistry Molecular Approach
Chemistry: Structure and Properties
Chemistry: A Molecular Approach
Chemistry: A Molecular Approach
Principles of Chemistry: A Molecular Approach
Chemistry: The Central Science
Related questions
Experiment 1: Calculating Rate of Reaction
In this experiment you will calculate the rate of reaction of potassium iodide and hydrogen peroxide. The order of the reaction will also be determined.
Materials: 20 mL 3% Hydrogen peroxide, H2O2 | Stopwatch * You must provide *You must cut this piece of tubing into two, 12 inch pieces. (if you have not already done so). | |
Procedure
Preparation of Apparatus
Set up apparatus as shown in Figure 2. To do this, begin by labeling the Erlenmeyer Flasks as 1 and 2. The reaction will take place in Flask 1.
Fill Flask 2 approximately three quarters of the way full with water.
Press the 2-hole rubber stopper into the top of Flask 2. Place one three in. piece and one six in. piece of rigid tubing into each hole of the rubber stopper. This should create an airtight system.
Place the one-hole stopper on Flask 1, and fit the remaining 3 in. piece of rigid tubing in the stopper hole.
Connect Flask 1 and Flask 2 with the two, 12 in flexible tubing pieces. One piece should connect Flask 1 to Flask 2, and the second piece should connect Flask 2 to the graduated cylinder. The tubing which connects Flask 2 to the graduated cylinder should be positioned low enough to be immersed in the water in Flask 2.
Figure 2: Apparatus set-up. Note this is a sample set-up and is not drawn to scale. Your specific equipment may vary slightly. |
Part A: Preparation of Reactants
Pour five mL of the IKI solution into a 10 mL graduated cylinder.
Add five mL of distilled water to the graduated cylinder to bring the total volume to 10 mL. This is the 0.5% - 1.0% (diluted) IKI solution.
Pour 15 mL of 3% H2O2 solution into a 100 mL beaker.
Add five mL of distilled water to this beaker and mix with a stir rod. This is the 2.25% (diluted) H2O2 solution.
Part B: Performing the Reaction
Remove the stopper from Flask 1 and place five mL of the 3% (undiluted) H2O2 solution and 10 mL of the undiluted IKI solution provided into the flask. Immediately replace the stopper on the flask.
Note: At this point, you should select an extra beaker (any volume) from your lab kit to use as an supplemental collection container beaker for Step 6. You do not need to use the beaker yet, but keep it in close proximity.
Swirl Flask 1 until you observe a steady dripping of water going into the 10 mL graduated cylinder. This could take 3 - 5 minutes. Check for leaks in the tubing or system if water does not start rising up the plastic tubing coming from Flask 2 and traveling towards the graduated cylinder within one minute.
Stop swirling Flask 1 when you notice the steady flow of water droplets. When you stop, the water drop -rate will significantly decrease (to around one drop every 5 - 20 seconds) and could take a few minutes to stabilize. If a steady flow of drops of water does not occur within a few minutes, swirl Flask 1 for 1 more minute and check again. Repeat this process until there is a steady flow of drops of water after you have stopped swirling Flask 1.
Quickly empty liquid that has collected in the 10 mL graduated cylinder and replace the empty cylinder back under the flexible tubing.
Allow the flow of drops to become steady again. This could take 1 - 3 mL of water.
Start timing once the drop rate is steady and the volume of water collected is at a whole number (such as three mL). Record the time in Table 1 each time 2 mL of is water displaced. Continue taking data until you have at least 10 data points (20 mL displaced).
Note: Use the extra beaker (located in Part B: Step 1) to collect additional fluid when the volume of displaced water exceeds 10 mL.
Return the collected water from your 10 mL graduated cylinder to Flask 2. Ensure the seal is air tight.
Empty, clean and dry Flask 1 and the graduated cylinder.
Repeat Steps 1 - 8 for the following trial conditions: 5 mL 3% (undiluted) H2O2 mixed with 10 mL of 0.5%-1.0% IKI solution (placed in Flask 1); and, 5 mL of 2.25% H2O2 mixed with 10 mL of 1.0%-2.0% IKI solution (placed in Flask 1). Record the data in Table 2 and Table 3, respectively.
Note: Clean the graduated cylinder and extra collection beaker before it is used to measure any additional reagents for Trial 2 or Trial 3; and, before it is used for collecting the water from the reaction in the apparatus.
Use a graphing software program to make a graph of each trial. The graph should demonstrate the relationship formed between time vs. mL of water displaced.
Find and record the slope and the inverse slope for each trial.
Table 1: 10 mL Undiluted (1.0 -2.0%) IKI and 5 mL 3% H2O2 | |
mL water displaced | Time (seconds) |
2 | |
4 | |
6 | |
6 | |
8 | |
10 | |
12 | |
14 | |
16 | |
18 | |
20 | |
22 | |
Slope: | |
Inverse Slope: |
Table 2: 10 mL Diluted (0.5-1.0% IKI) and 5 mL 3% H2O2 | |
mL water displaced | Time (seconds) |
2 | |
4 | |
6 | |
6 | |
8 | |
10 | |
12 | |
14 | |
16 | |
18 | |
20 | |
22 | |
Slope: | |
Inverse Slope: |
Table 3: 10 mL Undiluted (1.0 -2.0%) IKI and 5 mL 2.25% H2O2 | |
mL water displaced | Time (seconds) |
2 | |
4 | |
6 | |
6 | |
8 | |
10 | |
12 | |
14 | |
16 | |
18 | |
20 | |
22 | |
Slope: | |
Inverse Slope: |
Calculations
Post-Lab Questions
1. Determine the order of the KI in this reaction.
2. Determine the order of the H2O2 in this reaction.
3. Calculate the rate law constant.
4. What is the overall rate law?
5. When finding the order of H2O2, why was Trial 1 and Trial 3 used?
6. When finding the order of KI, why was Trial 1 and Trial 2 used?
7. Research and identify some alternative catalysts that could be used to accelerate the decomposition of hydrogen peroxide. Evaluate these catalysts and determine which option is